FLOW SENSOR
• Measurement Principle: Differential pressure
• Flow Range: 20 … 200 m³/s
• Bidirectional Measurement: Standard
• Recommended Pipe Diameter: 50 mm and above
• Reference Conditions: 0 °C, 1013.25 mbar - DIN 1343
• Gases: Wet* and dry compressed air, nitrogen, and inert gases
PRESSURE SENSOR
• Pressure Sensor Range (standard): 0 ... 16 bar
TEMPERATURE SENSOR
• Temperature Range: -40 … 150 °C (avoid icing)
DATA OUTPUTS
• Digital: RS485, MODBUS RTU protocol
• Analog: 4 … 20 mA single analog output (configurable via VPStudio software)
DISPLAY / DATA LOGGER
• Technology: Liquid Crystal Display (LCD)
• Backlight: Blue, automatic power-saving
• Data Logger: 2 million data memory capacity
MECHANICAL & ENVIRONMENTAL
• Probe Length: 386 mm
• Process Connection: Compression fitting, 0.5” NPT thread
• Pressure Resistance: PN16
• Protection Class:
– IP52 | NEMA 12 (when display module is attached; avoid inverted installation)
– IP63 | NEMA 4 (when connector cap is attached; avoid inverted installation)
• Operating Ambient Temperature: 0 … 60 °C (avoid direct sunlight and radiant heat)
• Wetted Materials: Anodized aluminum, stainless steel 316, glass, epoxy
• Corrosion Resistance: Avoid highly abrasive or acidic environments
ELECTRICAL
• Connection Type: M12, 5-pin connector (female)
• Power Supply: 12 ... 24 VDC, Class 2 (UL)
• Power Consumption: 3.6 Watts
• Current: 150 mA at 24VDC (constant over entire flow range)
CERTIFICATIONS
• UL / CUL: 14 AZ, Industrial Control Equipment
• CE: EN 61325-1 (2006) Class A, EN 61000-6-1 (2007)